RDT result ==> PASS!

Total Run Time(H:M:S) = 2:14:41
Total fail Counts = 0
Erase fail Counts = 0
Program fail Counts = 0
Read fail Counts = 0
Highest Recorded Temperature = 85'C
RDT firmware version = S0130A0
RDT firmware version (from Result) = S0130


=== RDT SETTING =========================================
SLC => Test Loop = 4, ECC TH = 20 bits
Non-SLC => Test Loop = 4, ECC TH = 50 bits
RDT Read Retry => Disable
Bypass status fail bit => Disable
Force single plane program => Disable
Delay 30 minutes to read check => Disable
Pre-Check good block quantity => Disable
Spectek NAND special test => Disable
Erase soon after read check => Disable
Max Active Interleave Way => 8-Way 
Thermal Throttling Temperature => 90'C 
Thermal Throttling Flash Clock => 50Mhz 
Test Block Cnt => All blocks
Test Type => Write All Block then Read
Test Mode => Erase  +  Program  +  Read  
Read Type => Read check for all loop
Reference Mode => Ref pretest bad block Mode
TemperatureTH => Don't care
EraseFailCntTH => Don't care
ProgFailCntTH => 3 counts
ReadFailCntTH => Don't care
BadBlockCntTH/Die => Don't care
=========================================================

<< Bad Block Count Distribution >>
-------------------------------------
       CH0   CH1   CH2   CH3   (All-Plane)
CE0    000   000   000   000   
CE1    000   000   000   000   
CE2    000   000   000   000   
CE3    000   000   000   000   
CE4    000   000   000   000   
CE5    000   000   000   000   
CE6    000   000   000   000   
CE7    000   000   000   000   

       CH0   CH1   CH2   CH3   (Plane-0)
CE0    000   000   000   000   
CE1    000   000   000   000   
CE2    000   000   000   000   
CE3    000   000   000   000   
CE4    000   000   000   000   
CE5    000   000   000   000   
CE6    000   000   000   000   
CE7    000   000   000   000   

       CH0   CH1   CH2   CH3   (Plane-1)
CE0    000   000   000   000   
CE1    000   000   000   000   
CE2    000   000   000   000   
CE3    000   000   000   000   
CE4    000   000   000   000   
CE5    000   000   000   000   
CE6    000   000   000   000   
CE7    000   000   000   000   
-------------------------------------


<< Bad Block information >>
-------------------------------------------------------------------------------------------------------
                    Seq    Block     Page      Loop   Mode  MaxECC    CE    Channel  Lun   Plane  Temp 